Fabricke parametre za Ecospar Alba/Auriga

RECOMMENDED SETTINGS 
0. Fuel ignition timeout --> [20] 36. Power 3 fan 2 speed --> [0]
73. User fuel feeder 1 ON time factor -->
[100]
1. Ignition test timeout --> [10] 37. Power 4 fan 2 speed --> [0] 74. User fuel fan 1 speed factor --> [100]
2. Fuel type --> [0] 38. Power 5 fan 2 speed --> [0] 75. Wood fuel fan 1 speed factor --> [100]
3. Heat up feeder OFF time --> [210] 39. Quickheat fan 2 speed --> [0] 76. Selected configuration --> [1]
4. Heat up feeder ON time --> [110] 40. Stop fire fan 3 speed --> [240] 77. 2nd room temperature --> [0.0]
5. Fuel ignition feeder 1 OFF time -->
[200] 41. Test fire fan 3 speed --> [240] 78. Flame ON level --> [0]
6. Fuel ignition feeder 1 ON time --> [20] 42. Heat up fan 3 speed --> [240] 79. Flame OFF level --> [0]
7. Ignition test feeder 1 OFF time -->
[100] 43. Fuel ignition fan 3 speed --> [240] 80. Flame OFF detection delay --> [0]
8. Ignition test feeder 1 ON time --> [10] 44. Ignition test fan 3 speed --> [240] 81. Underpressure setpoint --> [0]
9. Power 1 feeder 1 OFF time --> [1] 45. Power 1 fan 3 speed --> [240]
82. Min. (error) underpressure/airflow -->
[0]
10. Power 1 feeder 1 ON time --> [13] 46. Power 2 fan 3 speed --> [240]
83. Underpressure/airflow error delay -->
[0]
11. Power 2 feeder 1 OFF time --> [1] 47. Power 3 fan 3 speed --> [240] 84. Accumulator temperature --> [0]
12. Power 2 feeder 1 ON time --> [1] 48. Power 4 fan 3 speed --> [240] 85. T1-T2 for water pump OFF --> [0]
13. Power 3 feeder 1 OFF time --> [1] 49. Power 5 fan 3 speed --> [240]
86. Boiler to accu. temperature drop -->
[0]
14. Power 3 feeder 1 ON time --> [1] 50. Cool fluid exit temp. diff. --> [10] 87. Keep fire fan 1 speed --> [0]
15. Power 4 feeder 1 OFF time --> [1] 51. Water/air temperature --> [38.0] 88. Keep fire feeder 1 ON time --> [0]
16. Power 4 feeder 1 ON time --> [1]
52. Water temperature in stove mode -->
[80] 89. Keep fire fan 1 duration --> [0]
17. Power 5 feeder 1 OFF time --> [1] 53. Cool fluid entry temp. diff. --> [10] 90. Keep fire period --> [0]
18. Power 5 feeder 1 ON time --> [33]
54. Ignition test gases temperature -->
[80] 91. Feeder 2 delay/ON time factor --> [0]
19. Stop fire fan 1 speed --> [240]
55. Modulation start gases temperature -
-> [320] 92. Pellets quality --> [1]
20. Test fire fan 1 speed --> [140]
56. Heating device OFF gases
temperature --> [75] 93. Wood quality --> [1]
21. Heat up fan 1 speed --> [150]
57. Maximum (error) gases temperature -
-> [340] 94. Time to service --> [0]
22. Fuel ignition fan 1 speed --> [160]
58. Fan 2 as ambient min. gases temp. -->
[100]
95. Stove cool fluid entry temp. diff. -->
[5]
23. Ignition test fan 1 speed --> [170]
59. No fuel (error) gases temperature -->
[60] 96. Stove cool fluid exit temp. diff. --> [2]
24. Power 1 fan 1 speed --> [150] 60. Fan 1 blow cleaning period --> [60] 97. T1-T2 for min. modul. speed --> [0]
25. Power 2 fan 1 speed --> [0] 61. Fan 1 blow cleaning duration --> [45] 98. Full level --> [0]
26. Power 3 fan 1 speed --> [0] 62. Fan 1 blow cleaning speed --> [240] 99. Low level --> [0]
27. Power 4 fan 1 speed --> [0] 63. Air pulse cleaning duration --> [0] 100. Empty level --> [0]
28. Power 5 fan 1 speed --> [200]
64. Chamber cleaning duration/rot. -->
[0] 101. Blow out duration --> [180]
29. Test fire fan 2 speed --> [0] 65. Ash extraction auger duration --> [0] 102. Antifreeze temperature --> [0]
30. Stop fire fan 2 speed --> [0] 66. Ash extraction auger period --> [0] 103. Water pump minimum speed --> [0]
31. Heat up fan 2 speed --> [0] 67. ON temperature --> [40] 104. Water pump maximum speed --> [0]
32. Fuel ignition fan 2 speed --> [0]
68. OFF temp./T1-T2 for
max.modul.speed --> [35] 105. Reserved 105 --> [0]
33. Ignition test fan 2 speed --> [0] 69. Anti-condensation exit temp. --> [0]
73. User fuel feeder 1 ON time factor -->
[100]
34. Power 1 fan 2 speed --> [0] 70. Heat up duration --> [160] 74. User fuel fan 1 speed factor --> [100]
35. Power 2 fan 2 speed --> [0]
71. Fuel ignition temp. check samples -->
[6] 75. Wood fuel fan 1 speed factor --> [100]
0. Fuel ignition timeout --> [20] 72. Fuel ignition temperature rise --> [2] 76. Selected configuration --> [1]


Ovo nisu idealne parametre, vec ako nesto zabrljate da se vratite na fabricki podesheno. Redosled je malo pobrkan zbog copy/ paste

januar 31, 2020 u Drugo - MartinMKD | 3,050 pregleda

Morate biti ulogovani ili registrovani da bi odgovorili na ovo pitanje.

Povezana pitanja

Dobrodošli na sajt Grejanje na Pelet. Ovde možete pronaći odgovor na sve što vas interesuje vezano za grejanje na pelet.
Saznajte iz prve ruke prednosti i mane grejanja na pelet. Koliko koja peć troši, koji pelet se pokazao kao najkvalitetniji prošle godine.
Postavi Pitanje